GETA 1000 ALARM
MONITORING CENTER

TECHNICAL
SPECIFICATIONS
- It has 80C51
microprocessor.GETA 1000, is designed and
produced by microprocessor control technology.
- This program is
saved in EPROM.It is not effected by the no
power.
- The events that
happen while it is working , can be seen on the
LCD display.The events can be seen on the LCD
display as 4/2 forming and can be seen 4/11
forming in Contact ID format.There; the first 4
digit are account code and the second two digit
are the events codes.On this display , the date
and the time can be seen at the same time.The
time and the date can be changed by two buttons
and supervised by the key.
- All the events
including the coming signals and the troubles
that occur can be seen on the LCD display and can
be printed by the printer .All the alarm signals
can be resetted by acknowledge button.
- All the events
can be sent to the computer by RS-232
port.GETA1000 sends the Radionics 6500 format as
serial ASCII data at 1200 baud: 8 data bits, 1
Stop bit and Even parity.
- 9999 x 99
different alarm codes can be received from one
telephone line.
- There is an
automatic " watchdog" system .If the
program stops running , The "watchdog"
system resets the microcontroller and then
program begins running again.Despite this , if
the program doesn't start running , trouble led
begins flashing.
- The telephone
line can be controlled by the 3 minutes
intervals.If a problem is recognized , the "
line fault " led begins to light.
- The device
controls the printer line and the printer working
.If a problem is recognized , the message "
PRINTER ERROR " is written on the LCD
display and also gives an buzzer sound .
- There is
automatic battery charge and decharge control.
- The device
controls its battery voltage and if recognises a
reduce in the voltage (under 11 volts), the
message "LOW BATTERY " is written on
the LCD display and also gives a buzzer sound.
TELECOMMUNICATION
SPECIFICATIONS
COMMUNICATION FORMATS
| NAME |
HANDSHAKE |
DATA |
BOUD |
FORMAT |
EXTENDED |
KISS OFF |
| Geta |
2300Hz |
DTMF |
DTMF |
4/2 |
NO |
2300Hz |
| Contact ID
1400Hz |
Dual Tone |
DTMF |
DTMF |
4/2/1/3/2/3 |
NO |
1400Hz |
| Sur-Gard |
2300Hz |
DTMF |
DTMF |
4/2,4/3 |
NO |
2300Hz |
| Franklin |
2300Hz |
1800Hz |
20bps |
4/2 |
NO |
2300Hz |
| Radionics |
2300Hz |
1800Hz |
40bps |
4/2 |
NO |
2300Hz |
| Other
Pulse |
2300Hz |
1800Hz |
20-40bps |
4/2 |
NO |
2300Hz |
| Other
Pulse |
1400Hz |
1800Hz |
20-40bps |
4/2 |
NO |
1400Hz |
Working
Temperature: -20 ; + 50 C
Storage
Temperature: - 30 ; + 85 C
Working
relative humidity: %80.
TSEK
Quality Certification.
Türk
Telekom certification.
TSE
Product Quality Certification.